Features
● Industrial standard special isolated main power supply, meets CISPR32/EN55032 CLASSA; 
● The product has the function of input anti-reverse connection; 
● Achieved the certification of IEC60950,UL60950,EN60950;
● Optional isolation RS232/RS485/RS422; 
● Optional RS232/ RS485/ RS422 independent isolation power supply (5V to 5V), isolation voltage 3000V. 
● Isolated 485/422 insulation voltage 4KV, instantaneous peak voltage 560KV; 
● Support DIN V VDE V 0884-10 standard; 
● Isolation 485 complies with the IEC 60950-1 standard; 
● 485/422 effective isolation voltage 2500V; 
● Support synchronization, point-to-point, point-to-multiple point transmission; 
● Automatic signal detection rate; 
● Support power isolation, prevent current impact, effectively reduce signal interference.
● Prevent electrical interference and chemical corrosion; 
● Serial port transmission rate up to 256 KBPS; 
● Support 12V-52V wide voltage, power consumption < 1.5W; 
● 1500W surge protection, 15KV electrostatic protection; 
● Support multi-mode 5KM (dual fiber), single mode 20KM (single fiber, dual fiber) product selection; 
● Multi-mode transmission distance up to 5KM, single mode transmission distance up to 120KM (customized);
Technical Indexes
| Fiber index | |
| Wavelength | 1310-1550nm | 
| Data rate | 155Mbps | 
| Tx power | >-8db | 
| Rx sensitivity | >-24db | 
| Fiber connector | FC as default(SC/ST/LC optional) | 
| Date index | |
| Standard | Meets EIA RS-232,RS-485,RS-422 standard | 
| Physical connector | 7-Pin industrial terminal | 
| Bit rata | 50 bps to 256 kbps ( support non-standard bit rata ) | 
| Simultaneous use of ports | 2 | 
| RS232 | 3 wire system ( RXD、TXD、GND )、Full duplex、Point to Point communication | 
| Maximum communication distance 15 meters | |
| RS485 | 2 wire system ( A、B ) 、Half duplex、Point to multiple points communication | 
| Maximum communication distance 1219m, transmission rate inversely proportional to the transmission distance | |
| RS422 | 4 wire system full duplex | 
| Maximum communication distance 1219m, transmission rate inversely proportional to the transmission distance | |
| RS485 circuit index | |
| RS-485 pull-up resistor/pull-down resistor | 1 kΩ,150 kΩ | 
| RS-485 terminal resistor | N/A、120 Ω and 120 kΩ | 
| Delay | 300 ns | 
| Power index | |
| Input current | 25mA~125mA | 
| Input voltage | 12V~52V | 
| Overload current protection | Support | 
| Power supply connector | 3-Pin industrial terminal | 
| Power consumption | <1.5W | 
| Mechanical index | 
 | 
| Chassis | Aluminium alloy | 
| Product net weight | 0.65KG ( Pair ) | 
| Installation | Track type | 
| Environment index | |
| Operating temperature | -20°C ~ 75°C | 
| Storage temperature | -40°C ~ 85°C | 
| Operating humidity | 5 to 95%(Non-condensing) | 
| Working life | >100,000 hours | 
注:本产品有全国产化型号可选
Important Notice
Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.